The number of planning permits issued by the Kathmandu Valley Town Development Committee (KVTDC) is 22.
Planning standards to be followed as directed by KVTDC:
1. The road joining the planning areas should be 7 meters wide.
2. The road joining the blocks should be 5 meters wide.
3. The roads joining the plots should be 4 meters wide.
4. The width of the plot should be minimum 6 meters.
5. The minimum area of the plot should be 2 2.
6. There should be a provision for about 5 per cent open space in the area of 5-10 planning, 4 per cent in 10-25, 3.5 per
cent in 25-100 and 2.5 per cent open spaces above 100 of planning area.
7. There should be provision for various facilities like accessibil ity to drinking water, electricity, sewage system, telephone connection and the roadways able to carry the traffic of fire fighting vehicles.
source:KVTDC